CT26-Luc Cells
USD 800.00*
Products are shipped frozen on dry ice in cryotubes. Each cryotube typically contains 3 × 106 cells for adherent lines or 5 × 106 cells for suspension lines (refer to the batch CoA for details).
Información general
| Descripción | CT26-Luc is a bioluminescent derivative of the murine CT26 colon adenocarcinoma cell line, engineered to stably express a firefly luciferase reporter gene. The parental CT26 cell line was established from an N-nitroso-N-methylurethane-induced undifferentiated colon carcinoma in a BALB/c mouse and is one of the most widely used syngeneic tumor models for preclinical immuno-oncology research. CT26 cells exhibit aggressive growth characteristics, including rapid proliferation and high tumorigenic potential in immunocompetent BALB/c hosts, closely mimicking aspects of human colorectal cancer biology. The stable integration of a luciferase reporter in CT26-Luc enables sensitive, quantitative bioluminescent imaging (BLI) of tumor burden in living animals. Following administration of the luciferin substrate, the emitted light signal correlates with metabolically active tumor cell number, facilitating noninvasive longitudinal monitoring of tumor growth, metastatic dissemination, and treatment responses. This makes CT26-Luc especially valuable for preclinical studies evaluating checkpoint inhibitors, therapeutic antibodies, oncolytic viruses, and combination treatment strategies in an immune-competent setting. CT26-Luc retains the key biological features of the parental CT26 line, including its sensitivity to immune-mediated killing and its established use in studies of tumor immunology, adoptive cell therapy, and cancer vaccine development. The addition of the luciferase reporter substantially increases experimental throughput and sensitivity, enabling real-time assessment of therapeutic efficacy and tumor kinetics over the course of treatment without sacrificing animals at individual time points. |
|---|---|
| Organismo | Mouse |
| Tejido | Colon |
| Enfermedad | Colon adenocarcinoma |
| Sinónimos | Luciferase Reporter CT26 Cell Line |
Características
| Raza/Subespecie | BALB/c |
|---|---|
| Edad | Age unspecified |
| Género | Female |
| Morfología | Fibroblast |
| Propiedades de crecimiento | Adherent |
Datos normativos
| Referencia | CT26-Luc (Cytion catalog number 305646) |
|---|---|
| Nivel de bioseguridad | 1 |
| NCBI_TaxID | 10090 |
| N.º de acceso de Cellosaurus | CVCL_E3H3 |
| Estado de los OGM | GMO-S1: This CT26 colon carcinoma derivative contains a lentiviral-Luc reporter cassette for bioluminescent tumor monitoring. This classification applies only within Germany and may differ elsewhere. |
Datos biomoleculares
| Perfil mutacional | Mutation: p.Gly12Asp, Homozygous |
|---|
Manejo
| Medio de cultivo | RPMI 1640, w: 2.0 mM stable Glutamine, w: 2.0 g/L NaHCO3 (Cytion article number 820700a) |
|---|---|
| Suplementos | Supplement the medium with 10% FBS |
| Reactivo de disociación | Accutase |
| Tiempo de duplicación | 24-48 hours |
| Subcultivo | Remove the old medium from the adherent cells and wash them with PBS that lacks calcium and magnesium. For T25 flasks, use 3-5 ml of PBS, and for T75 flasks, use 5-10 ml. Then, cover the cells completely with Accutase, using 1-2 ml for T25 flasks and 2.5 ml for T75 flasks. Let the cells incubate at room temperature for 8-10 minutes to detach them. After incubation, gently mix the cells with 10 ml of medium to resuspend them, then centrifuge at 300xg for 3 minutes. Discard the supernatant, resuspend the cells in fresh medium, and transfer them into new flasks that already contain fresh medium. |
| Relación de división | 1 to 3 |
| Densidad de siembra | 1 to 3 x 104 cells/cm2 |
| Renovación de fluidos | 2 to 3 times per week |
| Medio de congelación | As a cryopreservation medium, we use complete growth medium + 10% DMSO for adequate post-thaw viability. |
| Descongelación y cultivo de células |
|
| Atmósfera de incubación | 37°C, 5% CO2, humidified atmosphere. |
| Condiciones de envío | Cryopreserved cell lines are shipped on dry ice in validated, insulated packaging with sufficient refrigerant to maintain approximately −78 °C throughout transit. On receipt, inspect the container immediately and transfer vials without delay to appropriate storage. |
| Condiciones de almacenamiento | For long-term preservation, place vials in vapor-phase liquid nitrogen at about −150 to −196 °C. Storage at −80 °C is acceptable only as a short interim step before transfer to liquid nitrogen. |
Control de calidad y análisis molecular
Certificado de análisis (CoA)
| Número de lote | Tipo de certificado | Fecha | Número de catálogo |
|---|---|---|---|
| 305646-260326 | Certificado de análisis | 15. May. 2026 | 305646 |